Radio Surgery
 

Ellman
Ellman International, USA

Surgitron Dual Frequency redefines your surgical results with 4.0 MHz Radiowave Technology
The patented Surgitron Dual Frequency unit represents advanced radiowave technology that provides unparalleled surgical control, precision, versatility and safety.
The high frequency of 4.0MHz minimizes heat dissipation and thus cellular alteration. Clinical benefits include reduced post-operative discomfort, minimal scar tissue formation, maximum readability of histologic specimen, enhanced healing and excellent cosmetic results.
Ellman’s technology has received worldwide acclaim and recognition from leading surgeons, clinics, universities and authors.

 
Features
  • Patented Technology reflecting over 40 years of innovation and enhancement  
  • Dual Frequency combining two optimal frequencies for maximum surgical benefits  
  • Digital Operation for accurate parameter selection and viewing  
  • Solid State Circuitry for dependable, consistent energy emission  
  • Five Distinct Waveforms providing procedure / specific tissue treatment options  
  • Monopolar and Bipolar Functions resulting in beyond-electrosurgery control and precision  
  • 120 Watt Output; maximum power needed for all surgical environments  
  • Visual and Audible Safety Indicators to ensure maximum patient safety  
  • Parameter Recall allows rapid set-up for subsequent procedures  
  • Multi-Specialty Applications; all medical disciplines benefit from the technology  
  • Wide Delivery System Selection with constant expansion for emerging medical procedures  
  • Ergonomic Design including simple menu format and low-profile design which permits ease of set-up and function by staff

Five Distinct Waveforms for Optimum Results

1. Fully Filtered - Cut

• Micro-smooth cutting
• Negligible lateral heat
• Minimal cellular destruction
• Ideal for skin incision and biopsy.
• Best cosmetic results. Fastest healing

2. Fully Rectified - Cut/Coag

• Cutting with hemostasis
• Ideal for sub-cutaneous tissue dissection and planing. Especially useful in vascular areas while producing minimal amounts of lateral heat and tissue damage

   

3. Partially Rectified - Coag

• Coagulation / Shrinkage
• Ideal for cutting with hemostatic control
• Hemostasis with controlled penetration

4. Fulguration

• Maximum penetration and hemostasis
• Ideal for intentional tissue destruction

   

5. Bipolar

•-Pinpoint, micro-coagulation
• No tissue adherence to forceps
• No charring or tissue necrosis
• Ideal for coagulation in and around critical anatomy

 

Specifications

Mode

Output
Waveform

Output Frequency

Maximum
Output Power

Cut

90% Cut
10% Coag

4.0 MHz

120W

Cut/Coag

50% Cut
50% Coag

4.0 MHz

90W

Hemo

10% Cut
90% Coag

4.0 MHz

60W

Fulgurate

Spark - Gap

4.0 MHz

45W

Bipolar

Same as Hemo

1.7 MHz

120W

SIZE: 9”W x 5”H x 13 1/4”D WEIGHT: 18 lbs.

 

 